18
You can view any of the eight possible
zones assigned to the group by using |
or ¬, or pressing the hot key (1 to 8).
Group 01 Zone >1
Zone >----
4. Press [ if you want to edit the zone
number. You will see that the bottom
line contains a ">" to indicate that you
are in edit mode.
5. After entering the zone number, press
[ to save changes. Alternatively, press
] to exit without saving.
6. Now you can do one of the following:
Continue from step 3 to specify
more zones in the shunt group.
Press ] to return to step 2, which
allows you to set up another shunt
group.
Press ] twice to exit from the option.