4 Communication trouble reporting
The IRIS Touch 600 range simulates the Coopers 8750 Ethernet module, but allows for dual
path communication and monitoring (Ethernet & GPRS).
Due to the current interface implemented to the Coopers I-ON panel, when the IRIS Touch
has communications faults the following indication is report via the panel keypad.
Symptoms
Panel Status
Monitoring Centre
Alarm.
Ethernet Synchronisation
IRIS 620:
Ethernet Line Fault
IP Polling Fault
NT9004:
Ethernet trouble
IRIS 640:
No indication reported
NT9004:
Ethernet trouble
Ethernet Poll fail
IRIS 620:
IP Polling Fault
NT9014:
Ethernet trouble polling
IRIS 640:
No indication reported
NT9014:
Ethernet trouble polling
IRIS 640 only:
GPRS Registration
IRIS 640:
No indication reported
NT9003:
GPRS trouble
IRIS 640 only:
GPRS Poll fail
IRIS 640:
No indication reported
NT9013:
GPRS trouble polling
IRIS 640 only:
Ethernet + GPRS
Communication failure
Ethernet Line Fault
IP Polling Fault
NT9004:
Ethernet trouble
NT9003:
GPRS trouble
IRIS 640 only:
Ethernet + GPRS
Communication failure
IP Polling Fault
NT9014:
Ethernet trouble polling
NT9013:
GPRS trouble polling