Cooper Security i-on160EX User's Guide Page 64

  • Download
  • Add to my manuals
  • Print
  • Page
    / 104
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 63
4. Administration i-on160
Page 58
Once you have selected the Walk Test option you want to use:
The display shows a list of all
the detectors ready for testing.
The top line of the display
shows you how many
detectors remain to be tested.
10 Zone(s) to test:
Zone 001
10. Walk round and trigger each
detector. The display shows an
"A" at the end of the line for
each detector you trigger
successfully. If you have
enabled the Chime then every
time you trigger a detector the
keypads and loudspeakers give
a double tone chime.
Note that you cannot test PA,
24 hour or fire zones.
9 Zone(s) to test
Zone 001 A
11. Press if you want to see a
list of the zones that remain to
be tested:
Zones not triggered
Zone 003
12. Press X to end the test.
The control unit leaves walk
test mode and the bottom line
of the display shows the option
you were using.
WALK TEST
System >
Outputs
1. Make sure the display shows
the standby screen.
i-on160EX
12:20 02/11/2010
2. Press .
Enter Access Code
( )
3. Key in your access code (or
present a tag).
MENU
Omit Zones >
4. Press n until you see:.
MENU
Test >
Page view 63