3. After an Alarm
496930 Page 25
Set Fail Znn Setting failed because of zone nn.
Burg Znn Rstr Intruder alarm at zone nn restored.
Tamper Znn Tamper at zone nn.
Knn Missing Keypad nn missing.
Knn Restore Keypad nn restored.
Knn Tamper Tamper at keypad nn.
Knn Excess Keys Too many keys pressed at keypad nn (someone may be trying to
guess the access code).
Tel Line Fault Telephone line fault detected.
Tel Line Rstr Telephone line restored.
Comms Fail The communicator failed to report.
AC Fail Mains failed.
AC Restore Mains restored.
Low Battery Standby battery is low.
Low Batt Rstr Standby battery restored.
Batt Missing 12V supply from standby battery not present.
Batt Missing Rstr 12V supply from standby battery restored.
Aux DC Fail Power supply to wired detectors has failed.
Aux DC Fail Rstr Power supply to wired detectors restored.
In the log user codes are represented by numbers as follows:
U00 Installer U19 Idle
U01 User code 1 U21 Keyswitch
... ... U22 Remote Reset
U16 User code 16
Note that neither the Installer nor the user can erase the log.