Programming - Programming Commands 9651
Page 40 11772232
Value Attribute Valid for Description
A Armed in
Level A
All Always applied. The zone is armed when the
user selects Level A.
B Armed in
Level B
All When applied, the zone is armed when the
user selects Level B.
C Armed in
Level C
All When applied, the zone is armed when the
user selects Level C.
D Armed in
Level D
All When applied, the zone is armed when the
user selects Level D.
20: Change Engineer Code
Note: 9651 control units support six-digit access codes as well as the standard
four-digit codes. Command 56 sets the code length.
To change the Engineer Code:
1. Make sure you are in installer mode.
2. Press 20y
The display shows:
20:Code
3. Key in a new Engineer Code.
The display shows:
20:Code xxxx
4. Press y
5. Press y
21: Zone Configuration
This command enables you to select the wiring type of the zone connectors
on the control unit PCB. The default is option 0 for all models.
0 Up to 8 closed circuit loop zones (CC + Com A/T).
1 Up to 8 fully-supervised loop zones (FSL 2K2/4K7)
.
22: Loudspeaker Chime
In a single system, a user may find that the Chime tone from the keypads is
not loud enough. If so, use this command to make the internal sounder give
the Chime tone as well. If you select option 0, the internal sounder emits no
tone. Select a value from 1 (quietest) to 9 (loudest) to set the Chime volume
(the default is 5). The internal sounder demonstrates the volume when you
enter the digit.