Programming - Programming Commands 9651
Page 42 11772232
Text Alert lamp Service/Mains lamps
Panel Set 0
continuous
1
timed
0
continuous
1
timed
0
continuous
1
timed
No alerts Level set Level set
30s, then
T&D
Off Off On On* 30s
Alerts Level set Level set
30s, then
T&D
On On 30s On On* 30s
Panel Unset 0
continuous
1
timed
0
continuous
1
timed
0
continuous
1
timed
No alerts T&D T&D Off Off On On* 30s
Alerts T&D T&D On On On On* 30s
T&D Time and date * If a relevant condition exists
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 73) at
Grades 1, 2 and 3 requires that Command 28 is set to option 1.
29: Entry Alarm Delay Time
This command determines what the system does if a user strays from an
Entry Route zone during entry.
If you select option 0 (the default), the system gives an immediate alarm when
the user strays from an Entry Route zone during entry.
If you select option 1, the system gives an internal alarm when the user strays
from an Entry Route zone during entry but waits for 30 seconds before raising
a full alarm. The user can reset the system by entering an access code within
that time.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 73) requires
that Command 29 is set to option 1.
30: PA Response
When a Panic Alarm (PA) occurs, the system sends a PA message to the
Alarm Receiving Centre (ARC), if a communicator is fitted, and the keypad
shows the PA zone when a user disarms the system. With this option, you
can choose whether the system also operates the sounders.
Option
0 Sounders operate (default).
1 Sounders remain quiet.
Page view 45