Programming - Programming Commands 9651
Page 52 11772232
70: Level C Final Exit Operation
This command specifies how the system treats Final Exit zones during part
set C. If you select option 0 (the default), any Final Exit zones in Level C
continue to act as Final Exit zones during part set C. If you select option 1,
these zones act as Normal Alarm zones during part set C.
71: Level C Entry Route Operation
This command specifies how the system treats Entry Route zones during part
set C. If you select option 0 (the default), any Entry Route zones in Level C
continue to act as Entry Routes during part set C. If you select option 1, these
zones act as Final Exit zones during part set C.
72: Level C Exit Mode
This command sets the Exit Mode for Level C. The keypads give a double
"beep" confirmation tone at the end of all setting modes, including Silent Set.
The default is option 0, Timed.
Option
0 Timed. The keypad sounders and any internal sounders give a low
tone during exit of Level C. Use Command 75 to select the exit time.
1 Instant Set (no exit tone). Use this option to make the system set
without delay or exit tone.
2 Silent Set. Use this option to make the system set without an exit
tone. Use Command 75 to program the exit time.
3 Makes the Level C exit mode the same as Level A.
73: Level C Alarm Response
This command sets the Alarm Response for Level C.
Option
0 Keypad sounders only.
1 Internal sounders and keypad sounders (default).
2 Local alarm (internal and external sounder only).
3 Full alarm (communication and internal/external sounders).