Programming - Programming Commands 9651
Page 38 11772232
Value Type Description
14 Forbikobler
(FB)
This zone type is a Scandinavian type of Entry/Exit zone (the
word "forbikobler" means "bypass" in Danish). Use this type for
zones connected to standalone external keypads or access
controllers. If the zone is triggered by the external keypad during
the exit time, the control unit stops the exit time and sets the
system. If the zone is triggered while the system is set, the
control unit starts the entry time. Use zone attribute X7 to select
an entry timer for the zone (page 39) and Commands 201–4
(page 65) to set up the entry timers.
15 AC Fail (AC) This zone type is triggered by a failure in the AC input to an
external power supply. Command 134 defines whether a zone of
this type can be reset by a user or only by the installer.
Command 137 defines whether the user can override the fault to
set the system.
16 Low Battery
(LB)
This zone type is triggered by a low voltage in the battery in the
external power supply.
17 Battery Fault
(BF)
This zone type is triggered by a fault in the battery in the
external power supply.
18 Power Output
Failure (PF)
This zone type is triggered by a failure in the DC output to the
external power supply.
19 Fault (FL) This zone type triggers a fault condition, causing an alert and
preventing the system from being set. The tamper connection
operates in the same way as a normal alarm zone (type "NA").
Command 139 defines whether a zone of this type can be reset
by a user or only by the installer. Command 140 defines whether
the user can override the fault to set the system.
Zone Attributes
The following table shows the values available for zone attribute, depending
on the zone type. To set an attribute, key in the appropriate value. To unset
the attribute, key in the value again.
Value Attribute Valid for Description
X1
Chime (C) Normal Alarm
(NA)
Final Exit (FE)
Entry Route
(ER)
Shock Analyser
(SA)
When enabled by the user, the system makes
a doorbell-like sound when any zones
programmed as "Chime" are opened. This
facility operates only while the system is
unset.
To make the Chime available from keypad
sounders but not internal sounders, use
Command 22 with option 0.