Programming - Programming Commands 9651
Page 44 11772232
Note: The Alarm Abort period is controlled by the Alarm Receiving Centre
(ARC).
37: Daytime Tamper Communication
This command defines how the control unit reports tamper indications (for
example, an attempt to open a control unit or keypad case) while the alarm
system is unset.
Option
0 Internal sounder only (default).
1 Internal sounder and communication of tamper indication to the Alarm
Receiving Centre (ARC).
38: System Tamper User/Engineer Reset
This command defines how to reset the control unit after a tamper alarm (for
example, an attempt to open a control unit or keypad case).
To require an engineer reset, select option 1 (the default). To permit a user
reset provided that no fault exists, select option 0.
Note: This facility is independent of the options selected in Commands 31 and
33.
39: Level A Exit Mode
Use this command to select the exit mode for Full Set. The keypads give a
double "beep" confirmation tone at the end of all setting modes, including
Silent Set. The default is option 0, Timed.
Option
0 Timed. Use this option if the system sets after an exit time selected
using Command 44. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminated. Use this option if the user completes setting the system
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182 (see page 64).
2 Final Door Set. Use this option to complete setting of the system by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182 (see page 64).
3 Lock Set. To use this option, you must install a lock switch and
connect its contacts to the ET terminals of a keypad (refer to the 9x5x
Installation Guide). This facility is available on keypad software
version 1.4.2 onwards. See the notes below for more information.