9651 Programming - Programming Commands
11772232 Page 67
Setting Entry Timers for both FE and ER Zones
Suppose that you have installed a system that uses the Final Door exit mode.
In this case, the entry timer will usually be started when a user opens the final
door. It might seem unnecessary to assign an entry timer to an ER zone set
up inside but there are two types of situations which make it useful to do so.
1. In a house where the keypad is near the final door (for example, in the
hall), the entry time for a user coming through the door and unsetting the
system might be short (for example, 20 seconds). However, if the stairs
from the bedrooms descend into the living room (rather than the hall) and
you set up a detector there as an ER zone, users coming downstairs in the
morning may need longer to reach the keypad and unset the system.
Assigning a longer timer to the ER zone allows for this requirement.
2. If a final door develops a fault and has to be omitted from the system, the
control unit treats ER zones as FE zones and so they need entry timers.