7510r Technical Specification
Page 7
Power Supply
The internal power supply is an off-line switching type.
This product complies with the requirements of EN50131-
6 Type A power supply at Grade 2 and environmental
class 2.
Mains power supply 230VAC, 80mA max, 40mA
min, +10%/-15%, 50/60Hz
±5%.
Standby Battery 6 x 1.2V 2000mAh AA
rechargeable NiMH.
Standby time: more than 12
hours.
Max recharge time: less than
72 hours.
Monitoring includes Mains fail, battery low
voltage, battery failure.
Electromagnetic Compatibility
Immunity Conforms to EN50130-4.
Emissions Conforms to EN61000-6-3.
Outputs
O/P 1& 2 Voltage free, single pole relay
contacts rated 24VDC @ 1A
or 120VAC @ 0.5A.
Inputs
Zone 33 and 34 Fully Supervised Loop.
Fuses
The control unit has a T400mA mains fuse.
Electrical Safety
Conforms to EN60950-1.
Compliance Statements
This product is suitable for use in systems designed to
comply with PD 6662: 2004 at grade 2X and
environmental class II.
This product complies with the requirements of CLC/TS
50131-3:2003 at grade 2 and environmental class II.