7510r Programming Reference - Outputs
Page 23
When a partition holding this zone is set the control
unit starts an intruder alarm if the detector is
activated. See page 73 for instructions on how to set
the Activity Time.
Part Set
When a user instructs the control unit to part set, the
control unit sets only those zones with the Part Set
attribute. If a user performs a “Part Set All” then the
control unit sets all zones in the system with the Part
Set attribute. If a user part sets a partition then the
control unit sets only those zones within the selected
partition that have the part set attribute.
Force Set
The user can set the system while a zone with this
attribute is open (active). The control unit omits the
zone for the duration of the setting/unsetting cycle.
(You must enable this feature in the System Options -
Force Set menu See page 44.)
Note: Some attributes are not available for certain zone
types. The display shows the available attributes.
Outputs
The control unit provides 34 outputs. The first two
outputs are hardwired outputs, see Figure 4 on page 4
and Figure 9 on page 11 for the position of their
connectors.
Outputs 3 to 34 are radio outputs. The control unit uses
these outputs to command one or more of the radio
output devices compatible with the 7510r.
You can program the control unit to group outputs into
different "types". For each type the control unit has a
different pattern of activating or deactivating the output.
The pattern depends on whether the control unit is set or
unset, and what input is coming from the detectors or the
keypad. For either hardwired or radio outputs see Edit
Outputs for instructions.