Programming Reference - Outputs 7510r
Page 26
operates when the system is in alarm, and remains
active until the user disarms the system.
Note: For best results use this output type on a strobe
connected to a 770r Wireless Access Module. The
strobe on a 750r cannot respond correctly because of
the battery saving circuits within the radio siren.
Pulse Set
This output becomes active for a minimum of 1
second when any partition is fully set.
Pulse Unset
This output becomes active for 1 second when
someone unsets the system, or during a fire or PA
alarm.
Setting Complete
This output becomes active for 10 seconds when the
control unit finishes setting.
Siren P1 (to P4)
The control unit operates this output when the
selected partition is in alarm. See page 42 to choose
the siren delay and duration.
Strobe Set P1 (to P4)
This output is active for 10 seconds after the selected
partition has set. The output also operates when the
partition is in alarm and remains active until the user
disarms the partition.
Note: For best results use this output type on a
strobe connected to a 770r Wireless Access Module.
The strobe on a 750r cannot respond correctly
because of the battery saving circuits within the radio
siren.
Technical Alarm
This output becomes active during a technical alarm.
Medical
This output becomes active during a medical alarm.
PA
This output becomes active during a panic alarm.
Fire
This output becomes active during a fire alarm.