Programming Reference - System Options 7510r
Page 46
Alarm Confirmation
Note: This section of the manual describes the menus
available for programming the system to meet
DD243. For a description of how you may wish to
apply these menus see Appendix A.
In order to program your requirements for DD243 select
System Options, Alarm Confirmation
. The options available
are:
Confirmation Used
When set to ‘Yes’ this option enables the features
designed to ensure the system complies with
DD243:2004.
Note: When using Alarm Confirmation, and the system is
programmed for Installer reset after an alarm, the
user cannot set the system after an alarm until the
installer has carried out a reset.
Ext Sounder for
Unconfirmed: the control unit operates the external
sounder for all alarms (and overrides any Siren
Delay, see page 42).
Confirmed: the control unit operates the external
sounder for Confirmed alarms, but not for any other
types of alarm.
After Entry
Never: The control unit turns alarm confirmation off
if the user enters by the entry door (used for
DD243:2004 clauses 6.4.2 and 6.4.4).
2 zones: The control unit starts a confirmed alarm if
an intruder activates two (or more) zones after
entering the premises (used for DD243:2004 clauses
6.4.5).
Reset Unconf/Conf
This option works in conjunction with System Options -
User Access - Reset After Alarm
(see page 38) to
determine who can reset the system after a
confirmed or unconfirmed alarm. When programming
a control unit to meet BS8473:2006 first set System
Options - User Access - Reset After Alarm
to “N”. You may
then use the options below: