Programming Reference - Reporting 7510r
Page 60
SIA Report Restorals
If you have selected a SIA report mode in Reporting,
Alarms
then you can enable or disable restoral reporting
by selecting Reporting, Alarms, SIA Report Restore. The
options available are:
Disabled
Restore off. The system does not communicate
restorals.
Enabled.
Restore on. The system will communicate restorals,
as long as the SIA report mode you have selected
permits it (see page 57).
Contact ID Reports
If you chose Contact ID in Reporting Type menu then
select
Reporting
,
Alarms
,
Contact ID Reports
to select the
types of contact ID messages that the control unit sends.
There are two options:
Basic
Comprises all the messages with numbers in the “CID
Code” column of Table 1, with the exception of those
marked with an “‡”.
Basic + Restore.
With this option the system sends all the messages
with numbers in the “CID Code” column of Table 1.
Force Test Call Now
Use this option to make the control unit start a test call
immediately.
Dynamic Test Call
In dynamic testing the system makes a test call 24 hours
after the last alarm communication. To enable dynamic
testing select Reporting, Alarms, Dynamic Test Call, Enabled.
Static Test Call
In static testing the system makes a test call either at
one particular time of day or on one day every month.
To make test calls at a set time every day select
Reporting, Alarms, Static Test Call, Daily. From the display
select a number between 01 and 24 to choose the time of
day for the call. For example, select 18 to program the
Page view 63