Engineering Manual Text Keys
153
The user requirements are: full set, part set, and a second part set to allow a guest in Bedroom
3.
To program the system
Eng 1 Menu 1 – Program Zones
Zone Location Type (Hot Key) Attributes Wards Description
1011 Keypad1
Zone 1
Final Exit (7) 123 Front Door
1012 Keypad 1
Zone 2
Entry (9) 123 Hall
0001 Panel zone 1 Normal Alarm (1) 123 Garage Front
0002 Panel zone 2 Normal Alarm (1) 123 Garage Rear
0003 Panel zone 3 Normal Alarm (1) 123 Kitchen
0004 Panel zone 4 Normal Alarm (1) 123 Kitchen Door
0005 Panel zone 5 Normal Alarm (1) 123 Lounge
0006 Panel zone 6 Normal Alarm (1) 123 Lounge Door
0007 Panel zone 7 Normal Alarm (1) 1 Landing
0008 Panel zone 8 Normal Alarm (1) 12 Bedroom 3
The Entry attribute allows this zone to act as Final Exit in part set
(see option Eng1 Menu 3-2-16).
Assign Zones to Wards as shown and they will be armed in the corresponding Group
Eng 1 Menu 8 – Group Options
E1-8-1 Assign Groups
Group Wards
1 1
2 2
3 3
4 Not used (Leave as default) Note that M2000 provides
up to 8 Ward Groups)
E1-8-2 Exit Modes
Group Setting mode
1 Final Exit
2 Timed
3 Timed
4 Not in use (leave at default)
E1-8-3 Group Timers
Group Exit Entry Delay (Bell) Duration (Bell)
1 30 (default) 20 0 (default) 15 (default)
2 30 (default) 30 0 (default) 15 (default)
3 30 (default) 30 0 (default) 15 (default)
4 30 (default) 15 (default) 0 (default) 15 (default)
E1-8-4 Alarm Response
Group Alarm Response
1 Full (default)
2 Local
3 Local
4 Not in use (leave at default)