Engineer Menu 1-4 Engineering Manual
54
05 – Alarm
Activates when the selected ward has a full alarm (page 22); deactivates when the alarm
has been reset.
06 – P.A. Alarm
Activates when a PA Silent or PA Audible zone (page 23) triggers, or if a user code of type
Panic Code is used. The output activates only if the zone or user code belongs to the
selected ward. The output deactivates when all such alarms applicable to the ward have
been reset.
07 – Fire Alm.
Activates when any Fire zone (see page 23) that is in the selected ward triggers. The Unset
Fire attribute (page 37) determines whether the output activates only when the zone is set,
or when the zone is either set or unset. The output deactivates when all Fire alarms in
zones associated with the ward have been reset.
08 – Set
Activates when the selected ward is set; deactivates when the selected ward is unset.
09 – 2nd Entry
Activates when the selected ward's 2nd Entry Dly timer is running (page 63).
10 – 24Hr Alm.
Activates when a 24 Hour zone (page 22) in the selected ward goes into the alarm state if
the panel is unset; deactivates when the alarm is reset.
11 – Cnf Alarm
Activates when a confirmed alarm (page 89) is detected by a zone in the selected ward,
and remains active until reset.
12 – Zone Omit
Activates when any zone in the selected ward is omitted or shunted (e.g. by user option 1-
2 or 1-3); deactivates when all zones in the selected ward have the omits/shunts removed.
13 – Act. Omit
If a latching sensor (such as a door contact or break glass, but NOT a PIR) activates a zone
in the selected ward, and the zone remains active until the end of the confirmation time
(page 62), the control panel omits the active zone and triggers the Active Omit output.
The control panel deactivates the output when a user resets the system.
14 – 24Hr Omit
Activates when the selected ward has one or more 24 Hour zones omitted; deactivates
when the selected ward has all its 24 Hour zones reinstated.
15 – Set Fail
Activates when the selected ward fails to set (e.g. because a zone is active); deactivates
when the selected ward is reset.