Engineer Menu 1-9 Engineering Manual
90
Sndrs on Unconf – The control unit starts the internal sounders (including keypad
sounders) immediately after an unconfirmed alarm. This behaviour is also used if you have
selected Confirmation Off.
Sndrs on Confirm – The control unit activates the internal sounders after a confirmed
alarm and any programmed bell delay.
)
The sounders operate without a confirmed alarm if the Entry Delay timer (page 61)
has been started and has expired.
3 – Bells on Unconf / Bells on Confirm
These options are relevant only if you have selected Confirmation On.
Bells on Unconf (default) – The control unit activates the external bell output immediately
after an unconfirmed alarm. This behaviour is also used if you have selected Confirmation
Off.
Bells on Confirm – The control unit activates the external bell output after a confirmed
alarm and any programmed bell delay.
)
The external bell output operates without a confirmed alarm if the Entry Delay
timer (page 61) has been started and has expired.
)
Bells and strobes can be disabled for selected wards using the Bell & Strobe
attribute (page 37).
)
Refer to the Bell Delay and Bell Duration notes on page 61.
4 – After Entry Yes / After Entry No
These options are relevant only if you have selected Confirmation On.
After Entry No (default) – Choose this option if you want to prevent confirmed alarms from
occurring at all after the Entry Delay timer has expired.
Use this option to comply with
DD243:2002 paras 6.4.2, 6.4.3, 6.4.4 and 6.4.6.
After Entry Yes – Select this option if you want it to be possible for a confirmed alarm to
be generated once the Entry Delay timer (page 61) has expired. With this option selected,
if an intruder has started the Entry Delay timer (e.g. by breaking through the front door), a
confirmed alarm occurs only if either one or two further zones are triggered after the Entry
Delay timer expires. Only zone(s) that are not on the entry route are considered (i.e. zones
that have the Entry zone attribute are ignored).
Select the Confirm 2 Zones or Confirm 1 Zone option to choose whether one or two zone
activations are required after the Entry Delay timer (page 61) has expired.
5 – Ent KPD Lock Off / Ent KPD Lock On
These options are relevant only if you have selected Confirmation On.
Ent KPD Lock Off (default) – Users can unset the system from a keypad during the Entry
Delay time (page 61).
Ent KPD Lock On – Users cannot unset the system from a keypad during the Entry Delay
time (page 61).
Select this option if you are installing a system to comply with DD243:2002
paras 6.4.5 and 6.4.6. The user must unset the system with a proximity tag (“Portable ACE”)
or the Alarm Receiving Centre (ARC) unsets the system.