Engineer Menu 1-4 Engineering Manual
44
002 – Switch 12 Volts
Activates when any ward is set; deactivates when any ward goes into alarm or its Entry
Delay timer (page 61) is running, or when all wards are unset. This output is normally used
as an input to latching detectors.
003 – Detector Reset
Deactivates for approximately 4 seconds when a user code is entered to set the first ward.
The output is used to reset latching detectors (smoke detectors, shock sensors, etc.).
004 – Walk Test
Activates when a walk test is carried out (User option 1-1-2; see the
Manager's Manual
);
deactivates when the walk test is finished.
005 – Alarm
Activates when any ward has a full alarm (page 22); deactivates when all such wards have
been reset.
006 – Panic Alarm (PA)
Activates when any PA Silent or PA Audible zone (page 23) triggers, or if a user code of
type Panic Code is used. The output deactivates when all such alarms have been reset.
007 – Fire Alarm
Activates when any Fire zone (page 23) triggers. The Unset Fire attribute (page 37)
determines whether the output activates only when the zone is set, or when the zone is
either set or unset. The output deactivates when all Fire alarms have been reset.
008 – System Set
Activates when any ward is set; deactivates when all wards are unset.
009 – System Full Set
Activates when all wards are set; deactivates when any ward is unset.
010 – System Open
Activates when the system is unset; deactivates when any part of the system is set.
011 – Confirmed
Activates when there is a confirmed alarm (page 89), and remains active until the system is
reset.
012 – Courtesy Light
Activates for the duration of the Courtesy Time (page 64) when any ward has the Entry
Delay timer (page 61) running, or if any keypad is operated.
013 – Engineer On Site
Activates when the engineer’s code is entered; deactivates when the engineer is logged
off.