Engineer Menu 1-1 Engineering Manual
28
Confirmation On.
After Entry Yes.
Confirm 2 zones.
Step 3 – Select Attributes
Each zone can have one or more of the following attributes to alter its operation.
1– Access
Normal Alm zones programmed with this attribute are automatically isolated during the
entry or exit procedure to allow a "walk through" route to access the keypad or to exit.
The Entry zone type (page 24) performs the same function.
You may also want to apply this attribute to a Final Exit zone type to prevent the "zone in
fault triggered" tone when exiting.
2 – Double Knock
Zones programmed with this attribute will cause an alarm only if the zone is triggered a
specified number of times within the Double Knock period (page 63), or the zone remains
active for the whole of the Double Knock period.
The number of times the zone needs to be triggered is determined by the Double Knocks
counter (page 65).
3 – Soak Test
This attribute is useful if you want to place a zone under test. The attribute enables you to
find out whether activations of the zone have occurred, without the activations causing
alarms.
After setting the attribute, the zone is isolated for the period specified by the Soak Test
timer (page 63). If the zone is activated during this period, the activation is logged,
outputs of type Soak Test Fail (page 45) are triggered and the user is informed of the zone
failure after entering a user code. The test fail message is cleared only after entering the
Engineer's code.
If at the end of the test period no activations have occurred, the control unit removes the
attribute from the zone.
Note: The control unit resets the soak test time to zero whenever an engineer or installer
logs in or applies power to the control unit.
4– Omittable
Zones with this attribute can be omitted from the setting procedure by using User option
1-2 (see the
Manager's Manual
). If the Automatic Omits configuration option is selected
(page 85), zones that are active when the system is set are automatically omitted.
5 – Reset
This attribute is normally assigned to a zone that is connected to a vibration or smoke
detector. The zone is not monitored for approximately 12 seconds during the exit
procedure. This allows the sensor to stabilise, and prevents false alarms.