Cooper Security M2000 User's Guide Page 69

  • Download
  • Add to my manuals
  • Print
  • Page
    / 180
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 68
Engineering Manual Engineer Menu 1-5
61
2 – Entry Delay
When the ward is set and the entry procedure is initiated, either by activation of the Final
Exit zone (page 23) or by activation of a Normal Alm zone that has the Entry attribute
(page 29) set to Yes, the Entry Delay timer starts to count down. The timer should allow
the user sufficient time to enter a valid user code after entering the building. If a valid user
code has not been entered when the timer reaches zero, an internal alarm (page 22) is
generated and the 2nd Entry Dly timer (page 63) is started. If the 2nd Entry Dly timer
reaches zero, a full alarm is generated, unless overridden by option 1-8-4 (page 83).
3 – Bell Delay
When a full alarm is triggered for the selected ward, activation of the external bell and
strobe outputs can be delayed by the value of this timer. This timer or Sys Bell Dly (page
62) is used, depending on the setting of the Ward Bell Time/Global Bell Time configuration
option (page 86).
)
The Bell & Strobe ward attribute (page 37) determines which wards trigger the bell
and strobe outputs.
)
Bell Delay or Sys Bell Dly are considered to be zero if Bells on Unconf (page 90) is
selected.
4 – Bell Duration
When the Bell Delay for the selected ward has expired, the duration of the external bell
output can be controlled by the value of this timer. This timer or Sys Bell Dur (page 63) is
used, depending on the setting of the Ward Bell Time/Global Bell Time configuration
option (page 86).
)
If Confirmation On and Bells on Unconf are selected (page 89), the bell and strobe
outputs switch off and the system re-arms if a second zone does not trigger within
the Confirmation time (page 62). If a second zone does trigger, causing a
confirmed alarm, the bell output (but not the strobe) is switched off when the Bell
Duration or Sys Bell Dur timer has expired. Bell Duration and Sys Bell Duration are
started after any programmed bell delays.