Engineering Manual Engineer Menu 1-4
57
36 – PSU Fuse
Activates while a PSU Fuse zone (page 26) in the selected ward is active.
37 – PSU Mains
Activates while a PSU Power zone (page 26) in the selected ward is active.
38 – Mask Tamp
This is applicable only if the Mask Unset Tamp or Mask Set Tamper option is selected
(page 93). The output activates when a masking condition has been detected in the
selected ward (see page 26). The Anti Mask timer (page 63) delays activation of the
output.
39 – Mask Flt
This is applicable only if the Mask Unset Fault or Mask Set Fault option is selected (page
93). The output activates when a masking condition has been detected in the selected
ward (see page 26). The Anti Mask timer (page 63) delays activation of the output.
40 – Mask Alarm
The control unit operates this output when a suitably equipped detector reports masking
in its associated ward.
41 – Security
Activates when the selected Secure ward (page 37) is unset; deactivates when the Secure
ward is set.
42 – Supervision Fail
This output operates when there is a supervision failure on any radio zone allocated to the
ward programmed for this output. The output remains on until all supervision failures for
the ward are reset (see also option 1-9-3 17).
Note that to give a reliable indication of the location of the fault, you must assign each
MRNode to the appropriate ward (option 1-3-1), and each radio zone to the
appropriate ward (option 1-1).
43 – RF Jammed
The control unit operates this output when any MRNode reports jamming. The output
remains on until all jammed MRNodes report no jamming.
44 – Transmitter Low Battery
The control unit operates this output when any MRNode reports a wirefree detector with
low battery. (There is a separate output type for Telecommands and PAs.) The output
remains on until all MRNodes stop reporting detectors with low batteries.
45 – Telecommand Battery Low
The control unit operates this output when any MRNode reports a telecommand or PA
with low battery. The output remains on until all MRNodes stop reporting telecommands
or PAs with low batteries.